HVAC Code Lookup

Carrier Furnace Code 15

Soft lockoutShown as: 1 short flash, 5 long flashes

Blower motor lockout. The variable-speed blower failed to reach 250 RPM, or failed to communicate with the control within 30 seconds of being switched on, in two successive heating cycles. Auto-resets after 3 hours.

Manual wording: “15 BLOWER MOTOR LOCKOUT - Indicates the blower failed to reach 250 RPM or the blower failed to communicate within 30 seconds after being turned ON in two successive heating cycles.

Documented for: 58MVP, 58UVB and other variable-speed two-stage Carrier furnaces

Likely causes, most common first

  1. Failed blower motor or motor control module
  2. Loose or damaged blower motor wiring/communication harness

What you can safely check yourself

  • Check that the blower door is fully seated - the door switch removes power to the blower

When to call a technician

A variable-speed blower motor fault is a technician job; the motor, its module, and its harness all have to be tested.

A Carrier furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Other Carrier codes