HVAC Code Lookup

Trane Furnace Code E3.4

Soft lockout

The second-stage pressure switch will not close, so the furnace cannot go to high fire.

Manual wording: “Open Pressure Switch, 2nd Stage

Documented for: Two-stage S8V2, S9V2 and S9V2-VS furnaces

Likely causes, most common first

  1. Open pressure switch, 2nd stage
  2. Restricted or blocked venting
  3. Draft inducer not reaching high-stage speed
  4. Pressure switch tubing problem

What you can safely check yourself

  • Check the outdoor intake and exhaust terminations for blockage
  • Check the condensate drain and trap for a clog (condensing models)

When to call a technician

If the venting is clear, the second-stage pressure switch or inducer needs a technician.

A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Trane codes