Trane Furnace Code E3.1

Soft lockout

The first-stage pressure switch is reading closed when the control expects it to be open, which the control calls a shorted pressure switch.

Manual wording: “Shorted Pressure Switch, 1st Stage

Documented for: S8V2, S9V2 and S9V2-VS furnaces; on single-stage S8B1 the same code reads simply 'Shorted Pressure Switch'

Likely causes, most common first

  1. Shorted pressure switch, 1st stage
  2. Pressure switch contacts stuck closed
  3. Wiring fault across the pressure switch

When to call a technician

A stuck pressure switch is a safety-proving device. It must be tested and replaced by a technician, never jumpered.

A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.