Trane Furnace Code E2.1

Hard lockout

Retry exceeded. The furnace tried to light and never proved a flame, so the control has locked out for one hour.

Manual wording: “Retry Exceeded (Flame never sensed, one hour lockout after 3 times)

Documented for: S8B1, S8V2, S9V2 and S9V2-VS furnaces with the seven-segment IFC display

Likely causes, most common first

  1. Flame never sensed on repeated ignition attempts
  2. No gas or interrupted gas supply
  3. Failed igniter
  4. Dirty or failed flame sensor

What you can safely check yourself

  • Check that other gas appliances in the house work, which tells you gas is reaching the home
  • Check that the manual gas shutoff at the furnace has not been left closed after service
  • Reset once by turning the furnace switch off and back on

When to call a technician

If the furnace locks out again, stop resetting it. Repeated failure to light needs a technician to check the igniter, flame sensor, gas valve, and gas pressure.

A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.