HVAC Code Lookup

Trane Furnace Code E17

Hard lockout

The control is not getting a response from the ECM blower motor, so the indoor blower will not run.

Manual wording: “Blower motor no communication response

Documented for: S8V2, S9V2 and S9V2-VS furnaces with ECM blower motors

Likely causes, most common first

  1. Blower motor no communication response
  2. Loose or damaged motor communication harness
  3. Failed blower motor control module

What you can safely check yourself

  • Turn the furnace switch off and back on once to see whether the blower starts
  • Make sure the blower door is fully closed and latched

When to call a technician

Call a technician. The blower motor and its communication harness are inside the blower compartment and diagnosing them requires live testing.

A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.