Trane Furnace Code E09
Soft lockout
The inducer limit switch or the condensate pressure switch is open. On a condensing furnace this most often means condensate is backing up.
Manual wording: “Open Inducer Limit Switch or Condensate Pressure Switch”
Documented for: S9V2 and S9V2-VS condensing furnaces
Likely causes, most common first
- Open inducer limit switch or condensate pressure switch
- Blocked condensate drain, trap, or hose
- Frozen condensate in an outdoor-run drain line
- Full or failed condensate pump
- Inducer overheating
What you can safely check yourself
- Check the condensate drain line and trap for a clog and clear standing water from the drain pan area if you can reach it safely
- Check that any condensate pump is plugged in, not full, and pumping
- In freezing weather, check whether any part of the drain line runs somewhere cold enough to freeze
When to call a technician
If the drain and pump are clear, the inducer limit or condensate switch needs a technician. Do not bypass either switch.
A Trane furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.