Fujitsu Mini-Split Code 99

Soft lockoutShown as: OPERATION lamp blinks 9 times, TIMER lamp blinks 9 times, ECONOMY lamp blinking continuously

4-way (reversing) valve error. The control compared indoor coil temperature to room temperature and twice found the system running backwards for the selected mode, so the compressor stopped.

Manual wording: “4-Way Valve Error - When the indoor heat exchanger temperature is compared with the room temperature, and either following condition is detected continuously two times, the compressor stops.

Documented for: RL2, RLS2, RLS3, RLB/RLXB, RLF, RLF1, RGLX, RLE, LUAS1, LMAS, LZBS, LZAS, LPAS series

Likely causes, most common first

  1. 4-way valve stuck or not shifting
  2. Failed 4-way valve solenoid coil, or no voltage to the coil
  3. Loose molex plug at the valve coil
  4. Thermistor reading wrong (indoor coil or room sensor)

What you can safely check yourself

  • Note which mode the system was in when it failed - Fujitsu uses that to separate a valve fault from a control fault
  • Turn the power off at the disconnect for about 5 minutes and back on, then run the system and see whether it heats or cools correctly

When to call a technician

Testing the reversing valve, its solenoid coil, and the coil voltage is refrigeration and line-voltage work for a licensed technician.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.