Fujitsu Mini-Split Code 77

Soft lockoutShown as: OPERATION lamp blinks 7 times, TIMER lamp blinks 7 times, ECONOMY lamp blinking continuously

Heat sink thermistor error. The heat sink temperature sensor built into the power module is open or shorted.

Manual wording: “Heat Sink Thermistor Error - Heat sink temperature thermistor (built-in IPM) is open or shorted.

Documented for: RGLX, RL2/RLS3/RLB/RLXB, RLF/RLF1 outdoor units

Likely causes, most common first

  1. Failed inverter PCB (the sensor is built into the module on wall-mounted models)
  2. Erroneous connection or removed connector
  3. Thermistor resistance out of specification

What you can safely check yourself

  • Turn the power off at the outdoor disconnect and breaker for about 5 minutes, then restore power

When to call a technician

On wall-mounted models this sensor is part of the inverter board, so the fix is a board replacement by a licensed technician.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.