Fujitsu Mini-Split Code 72

Soft lockoutShown as: OPERATION lamp blinks 7 times, TIMER lamp blinks 2 times, ECONOMY lamp blinking continuously

Compressor thermistor error. The compressor body temperature sensor is open or short-circuited.

Manual wording: “Compressor Thermistor Error - Compressor temperature thermistor is open or short-circuited while power is on or running the compressor.

Documented for: RGLX, RL2/RLS3/RLB/RLXB, RLF/RLF1 outdoor units

Likely causes, most common first

  1. Erroneous connection or removed connector at the compressor thermistor
  2. Thermistor resistance out of specification
  3. Failed outdoor main PCB

What you can safely check yourself

  • Turn the power off at the outdoor disconnect and breaker for about 5 minutes, then restore power

When to call a technician

The sensor mounts on the compressor shell inside the condenser. Only a technician should replace it.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.