Fujitsu Mini-Split Code 41

Soft lockoutShown as: OPERATION lamp blinks 4 times, TIMER lamp blinks 1 time, ECONOMY lamp blinking continuously

Indoor room thermistor error. The room temperature sensor in the indoor unit has read an impossible temperature, meaning it is open or shorted.

Manual wording: “Indoor Room Thermistor Error - Room temperature thermistor detected an abnormal temperature.

Documented for: RGLX, RL2/RLS2/RLS3/RLB/RLXB wall mounted, RLF/RLF1 multi-zone

Likely causes, most common first

  1. Open or shorted room temperature thermistor
  2. Thermistor resistance out of specification
  3. Failed indoor controller PCB

What you can safely check yourself

  • Turn the power off at the breaker for about 5 minutes and back on to see whether the code clears

When to call a technician

The room thermistor is behind the indoor unit's front panel and has to be ohm-checked against Fujitsu's resistance table. Have a technician replace it.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.