HVAC Code Lookup

Fujitsu Mini-Split Code 39

Soft lockoutShown as: OPERATION lamp blinks 3 times, TIMER lamp blinks 9 times, ECONOMY lamp blinking continuously

Indoor fan motor power supply error. The indoor board has lost the supply feeding the fan motor, usually from a voltage drop, electrical noise, or an open connector.

Manual wording: “Check external cause at indoor and outdoor units (voltage drop or noise) ... Check if cable is open. (Upon correcting removed connector, reset the power)

Documented for: AUU18-48RGLX, ARU12-48RGLX

Likely causes, most common first

  1. Voltage drop or electrical noise from a large load sharing the same circuit
  2. Defective contact or leakage current in the power supply circuit
  3. Connector removed, mis-connected, or an open cable to the fan motor

What you can safely check yourself

  • Check whether a large appliance shares the same circuit and started at the same time the fault appeared
  • Turn the power off at the breaker for about 5 minutes and back on

When to call a technician

Connector and supply-circuit checks are inside the powered electrical box. Leave that to a technician.

A Fujitsu mini-split throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.