Coleman Furnace: 6 Flashes
A Coleman furnace LED pattern starting with 6 flashes matches 3 documented codes: 6 red flashes, 6 amber flashes (CP9C Echelon modulating), 6 red flashes (CP9C Echelon modulating). Watch the full pattern (short vs. long flashes) to tell them apart — all 3 are explained below.
Code 6 red flashes: While the furnace was running, the pressure switch opened four times during one call for heat
While the furnace was running, the pressure switch opened four times during one call for heat. The furnace locks out for one hour, then tries again on its own.
Manual wording: “6 RED FLASHES: This indicates that while the unit was operating, the pressure switch opened four times during the call for heat. Check for faulty inducer, blocked vent pipe or faulty pressure switch. The furnace will lock out for one hour and then restart.”
Documented for: TG8S, TGLS, TG9S, TM8X, TMLX, TM9X, TM8T, TM9T, TM8V, TM9V
Likely causes, most common first
- Faulty inducer (draft) motor
- Blocked vent pipe
- Faulty pressure switch
What you can safely check yourself
- Check the outside vent and intake pipe terminations for snow, ice, leaves or nests
- Check the condensate drain and trap for a clog
- Replace a dirty air filter
When to call a technician
If the pipes are clear and the furnace keeps dropping out, the inducer or pressure switch is failing and needs a technician.
A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installation Manual - Residential Gas Furnace, Models TG9S*MP, GG9S*MP (95.5% AFUE Single Stage Multi-position), 364861-UIM-G-1211 (Johnson Controls Unitary Products (Coleman), TG9S*MP, GG9S*MP 95.5% AFUE single-stage multi-position gas furnaces) · checked 2026-08-25
- Installation Manual - Residential Gas Furnace, Models TG8S*MP, TGLS*MP, GG8S*MP, GGLS*MP (Single Stage Multi-position / Low NOx), 356485-UIM-G-1211 (Johnson Controls Unitary Products (Coleman), TG8S*MP, TGLS*MP, GG8S*MP, GGLS*MP 80% AFUE single-stage gas furnaces) · checked 2026-08-25
- Installation Manual - Residential Gas Furnace, Models TM8X*MP, TMLX*MP (Single Stage Multi-position / Low NOx with High-Efficiency Motors), 437642-UIM-F-1211 (Johnson Controls Unitary Products (Coleman), TM8X*MP, TMLX*MP 80% AFUE single-stage gas furnaces with high-efficiency motors) · checked 2026-08-25
- Installation Manual - Residential Gas Furnace, Models TM9V*MP (Two Stage Variable Speed ECM), 701379-UIM-B-1211 (Johnson Controls Unitary Products (Coleman), TM9V*MP two-stage variable-speed ECM gas furnaces) · checked 2026-08-25
Code 6 amber flashes (CP9C Echelon modulating): Heat pump applications only: normal operation with a call for heat pump heating
Heat pump applications only: normal operation with a call for heat pump heating. Not a fault.
Manual wording: “Six Amber Flashes - (Heat Pump applications only) Normal operation with call for heat pump heating.”
Documented for: CP9C Echelon modulating furnaces paired with a heat pump
Likely causes, most common first
- Normal dual-fuel / heat pump heating operation
When to call a technician
No service needed.
A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation Manual - Residential Gas Furnace with ECM Motor, Models TP9C*C, YP9C*C, CP9C*C, LP9C*C (Up to 98% Modulating Multi-position), 681292-UIM-B-1211 (Johnson Controls Unitary Products (Coleman), CP9C*C Coleman Echelon modulating gas furnace (manual also covers the identical TP9C, YP9C and LP9C chassis)) · checked 2026-08-25
Full page for Coleman code 6 amber flashes (CP9C Echelon modulating)
Code 6 red flashes (CP9C Echelon modulating): Gas valve communication error
Gas valve communication error. The modulating gas valve and the control board have lost their data link, so the furnace cannot modulate or fire.
Manual wording: “Six Red Flashes - Gas valve communication error.”
Documented for: CP9C Echelon modulating furnaces
Likely causes, most common first
- Loss of communication between the control board and the modulating gas valve
What you can safely check yourself
- Turn the furnace off at the service switch for a minute and back on once
When to call a technician
Modulating gas valve communication faults are a technician job - the valve, its harness and the board all have to be checked.
A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Source
- Installation Manual - Residential Gas Furnace with ECM Motor, Models TP9C*C, YP9C*C, CP9C*C, LP9C*C (Up to 98% Modulating Multi-position), 681292-UIM-B-1211 (Johnson Controls Unitary Products (Coleman), CP9C*C Coleman Echelon modulating gas furnace (manual also covers the identical TP9C, YP9C and LP9C chassis)) · checked 2026-08-25
Full page for Coleman code 6 red flashes (CP9C Echelon modulating)