HVAC Code Lookup

Coleman Furnace: 10 Flashes

A Coleman furnace LED pattern starting with 10 flashes matches 2 documented codes: 10 red flashes, 10 red flashes (CP9C Echelon modulating). Watch the full pattern (short vs. long flashes) to tell them apart — all 2 are explained below.

Code 10 red flashes: The gas valve is energized with no call for heat

Safety faultShown as: Ten red flashes, then a two-second pause, repeating

The gas valve is energized with no call for heat. The main blower and inducer will run and no ignition sequence starts as long as the condition exists.

Manual wording: “10 RED FLASHES: Gas valve energized with no call for heat. The main blower and inducer blower will run and no ignition sequence will be started as long as this condition exists. Check gas valve and gas valve wiring.

Documented for: TG8S, TGLS, TG9S, TM8X, TMLX, TM9X, TM8T, TM9T, TM8V, TM9V

Likely causes, most common first

  1. Faulty gas valve
  2. Gas valve wiring fault

What you can safely check yourself

  • If you smell gas, leave the house and call the gas utility from outside

When to call a technician

The gas valve is being powered when it should not be. Call a licensed technician immediately - do not keep operating the furnace.

A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Full page for Coleman code 10 red flashes

Code 10 red flashes (CP9C Echelon modulating): Gas valve circuit shorted

Safety faultShown as: Ten red flashes, two-second pause, repeating

Gas valve circuit shorted.

Manual wording: “Ten Red Flashes - Gas valve circuit shorted. Check gas valve wiring. If correct, replace gas valve.

Documented for: CP9C Echelon modulating furnaces

Likely causes, most common first

  1. Shorted gas valve wiring
  2. Failed gas valve

What you can safely check yourself

  • If you smell gas, leave the house and call the gas utility from outside

When to call a technician

A shorted gas valve circuit is a gas-safety fault. Call a licensed technician and do not keep cycling the furnace.

A Coleman furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Source

Full page for Coleman code 10 red flashes (CP9C Echelon modulating)

Other Coleman codes