HVAC Code Lookup

Bryant Furnace Code 34.3

Safety faultShown as: Major code 34 on the LED (3 short, 4 long); 34.3 on the display

After successful ignition (flame proven), flame was lost after the heating blower on-delay.

Manual wording: “34.3 AFTER SUCCESSFUL IGNITION flame loss after heating blower on delay

Documented for: 926TC, 912SE

Likely causes, most common first

  1. Oxide buildup on the flame sensor
  2. Low inlet gas pressure
  3. Poor control ground continuity
  4. Airflow disturbing the flame

What you can safely check yourself

  • Check that the air filter is clean and supply/return vents are open

When to call a technician

Losing flame once the blower comes on often points at gas pressure or flame sensing. Have a technician measure flame current and manifold pressure.

A Bryant furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.

Sources

Other Bryant codes