American Standard Furnace: 2 Flashes
Code 2 Flashes: System lockout
Hard lockoutShown as: 2 flashes, pause, repeat
System lockout. The control tried and failed to establish or hold a flame enough times (retries or recycles exceeded) and has shut the furnace down.
Manual wording: “2 Flashes --- System Lockout (Retries or Recycles exceeded)”
Documented for: *UD1 / *DD1 and CUB1 / CDB1 fan-assisted gas furnaces with the LED-only integrated furnace control
Likely causes, most common first
- Loss of flame or gas supply failure - the control module retries the ignition sequence up to two times after the sensor cools, and if ignition is not achieved it will lockout the furnace
- Ignition failure at the burners
- Flame lost repeatedly during the heating cycle
What you can safely check yourself
- Check that other gas appliances in the house work, which tells you whether gas is reaching the home
- Check the thermostat is set to Heat and above room temperature
- Reset once by turning the furnace switch off and back on
When to call a technician
If the furnace locks out again after one reset, stop resetting it. Repeated ignition failure means the igniter, flame sensor, gas valve, or gas pressure needs a technician.
A American Standard furnace throwing this code repeatedly has a reason — clearing the code without fixing the cause just hides it.
Sources
- Installer's Guide - Upflow/Horizontal, Downflow/Horizontal Gas-Fired Furnaces, "Fan Assisted Combustion System" (18-CD19D7-17) (American Standard Heating and Air Conditioning, *UD1A/*UD1B/*UD1C/*UD1D upflow and *DD1B/*DD1C/*DD1D downflow 80% fan-assisted gas furnaces) · checked 2026-08-25
- Installation, Operation, and Maintenance Guide - Upflow Only and Downflow/Horizontal Gas-Fired Furnaces "Fan Assisted Combustion System" (Pub. No. 41-5010-20) (American Standard Heating and Air Conditioning, CUB1A/CUB1B/CUB1C/CUB1D upflow and CDB1A/CDB1B downflow 80% gas furnaces) · checked 2026-08-25
- Furnace Troubleshooting - American Standard owner support (American Standard Heating and Air Conditioning, American Standard residential gas furnaces (general)) · checked 2026-08-25